Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Main subject
Year range
1.
Arq. bras. cardiol ; 94(5): 651-655, maio 2010. tab
Article in Portuguese | LILACS | ID: lil-548112

ABSTRACT

FUNDAMENTO: Existem evidências indicando que o controle pressórico é mais efetivo na redução de complicações macrovasculares do diabete melito (DM) do que o controle glicêmico. No entanto, a redução da PA para os níveis recomendados pelas diretrizes é difícil na prática clínica. OBJETIVO: Avaliar o percentual de pacientes que apresentavam simultaneamente DM tipo 2 e hipertensão arterial sistêmica (HAS), atendidos em hospital terciário, com controle pressórico adequado, e determinar os fatores clínicos e laboratoriais associados. MÉTODOS: Estudo transversal com 348 pacientes com DM tipo 2 e HAS atendidos no ambulatório de Endocrinologia do Hospital de Clínicas de Porto Alegre. Os pacientes foram submetidos à anamnese, exame físico, com medida da pressão arterial (PA), e foi coletada amostra de sangue e urina para análise laboratorial. Os pacientes foram divididos em três grupos: controle pressórico ideal (< 130/80 mmHg), regular (130-139/80-89 mmHg) ou inadequado (≥ 140/90 mmHg). RESULTADOS: A média de idade foi de 61,2 ± 10,1 anos (46 por cento homens, 80 por cento brancos) e a duração do DM, 14,8 ± 9,5 anos. Do total de pacientes, 17 por cento apresentavam valores ideais de PA, 22 por cento regulares e 61 por cento inadequados. Os pacientes com controle inadequado da PA apresentavam maior duração do DM, cintura abdominal e glicemia de jejum. As demais variáveis foram semelhantes nos três grupos. CONCLUSÃO: A maioria dos pacientes avaliados apresentou controle inadequado da PA. Valores mais elevados de PA estão associados a um perfil clínico adverso, representado por maior duração do DM, obesidade abdominal, maior glicemia de jejum e complicações crônicas do DM.


BACKGROUND: There is evidence indicating that blood pressure control is more effective in reducing macrovascular complications of diabetes mellitus (DM) than glycemic control. However, the reduction in BP to levels recommended by international guidelines is difficult in clinical practice. OBJECTIVE: To assess the percentage of patients with both type 2 diabetes and hypertension (HBP) assisted in a tertiary hospital with adequate blood pressure control and to determine the clinical and laboratory factors related. METHODS: Cross-sectional study with 348 patients with type 2 diabetes and hypertension assisted in the outpatient clinic of Endocrinology, Hospital de Clínicas de Porto Alegre. Patients underwent history assessment, physical examination, with measurement of blood pressure (BP), and samples were collected from blood and urine for laboratory analysis. Patients were divided into 3 three groups: optimal (< 130/80 mmHg), regular (130-139/80-89 mmHg) or inadequate blood pressure control (≥ 140/90 mmHg). RESULTS: The mean age was 61.2 ± 10.1 years (46 percent men, 80 percent white) and DM duration, 14.8 ± 9.5 years. Eighteen per cent of the patients studied, 17 percent of patients had optimal BP value, 22 percent regular BP value and 61 percent inadequate BP value. Patients with inadequate BP control had longer diabetes duration, waist circumference and fasting glucose. The other variables were similar in 3 groups. CONCLUSION: Most patients assessed had inadequate BP control. Higher BP values are associated with an adverse clinical profile, represented by longer diabetes duration, abdominal obesity, higher fasting glucose and chronic complications of diabetes.


Subject(s)
Female , Humans , Male , Middle Aged , /epidemiology , Hypertension/epidemiology , Blood Pressure/physiology , Comorbidity , /physiopathology , Epidemiologic Methods , Hypertension/drug therapy , Hypertension/physiopathology , Reference Values , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL